VIRAMASK
with Viraseal tm Certifications
Blood Penetration Resistance.
FDA (21CFR PART 58) PROTOCOL 200600403-01 Lab No 315004 RESULTS - NOT
MEASURABLE
Flammability - FDA 16CFR PART 1610 Lab no 315005 RESULTS Flammability Class
1 - PASSED
Bacterial Filtration Efficiency (BFE) and Differential Pressure. FDA (21CFR
PART 58) LAB No 314853. PROTOCOL NO 200536208-01 STAPHYLOCOCCUS AUREUS ATC #
6538.
Results: % BFE > 99.9% Filtration Efficiency at 2.9 MM H2)/cm2 There were no
detected colonies on any of the Anderson Impactor Sampler Plates.
Viral Filtration Efficiency (VFE)
FDA(21 CFR PART 58) LAB NO315002 PROTOCOL NO200536209-01. BACTERIA PHAGE 0
X174 PER MIL-M-36954C and ASTM F2101
Results: > 99.9% VFE. There were no plaques detected in the Anderson
Impactor Sampler Plates.
Penetration Resistance at .3 MICRONS NaCl PER TSI 8130 AUTOMATIC FILTER
TESTER Test AREA 38.5cm2 @30 lpm NORMAL BREATHING RATE......
Results: .05% Penetration and
7.59 RES MM. Note: Same Conditions for N95 Material was 1.51% and 12.97MM
RES
Inhalation exhalation resistance per FDA Protocol NO 200600307-01
RESULTS.......10.5MM and 16MM LIMITS ARE 35MM MAX and 25MM MAX
PASSED......EXCELLENT
The VS-100OC
In addition the Activated carbon shows excellent adsorption against the
following:
Alcoholic beverages, automobile exhaust, body odors burned food, hydrogen
cyanide, hydrogen sulphide, diesel fumes, kerosene, kitchen odors, paints,
formaldehyde glues, perfumes, cosmetics, poison gases pollen popcorn and
candy, propane cheese , chlorine, fish odors, floral scents, garlic,
gasoline, onions, ozone, purification, resins, rubber, sauerkraut, smog,
sulphuric acid, tobacco smoke, fie smoke gases toilet odors varnish fumes -
Most VOC and VVOC
|